CS-6100R, CS-6100N, CS-6100P
SPECIFICATIONS
Type | CS-6100R | CS-6100N | CS-6100P |
Wiring Method | 2-Wire Type | 3-Wire Type | 3-Wire Type |
Switching Logic | SPST, Normally Open | Solid State Output, Normally Open | Solid State Output, Normally Open |
Sensor type | Reed Switch | NPN Current Sinking | PNP Current Sourcing |
Operating Voltage | 5~240V DC/AC | 5~30V DC | 5~30V DC |
Switching Current | 1 Amp. max. | 1 Amp. max. | 1 Amp. max. |
Contact Rating (NOTE 1) | 30W max. | 30W max. | 30W max. |
Current Consumption | - | 42mA@24V DC max. | 30mA@24V DC max. |
Voltage Drop | 3.5V max. | ||
Leakage current | - | 0.01mA max. | 0.01mA max. |
Indicator | Red LED | Power: Green LED,Output: Red LED | Power: Green LED,Output: Red LED |
Cable | Ø4.5 PVC - 24 AWG ( 0.22 mm² ) - 2 cores | Ø4.5 PVC - 24 AWG ( 0.22 mm² ) - 3 cores | Ø4.5 PVC - 24 AWG ( 0.22 mm² ) - 3 cores |
Operating Frequency | 200Hz | 1000Hz | 1000Hz |
Magnet Requirement (NOTE 2) | 80 Gauss | 75 Gauss | 75 Gauss |
Temperature Range | -10~70℃ (+14~158℉) | -10~70℃ (+14~158℉) | -10~70℃ (+14~158℉) |
Shock (NOTE 3) | 30 G | 50 G | 50 G |
Vibration (NOTE 4) | 9 G | 9 G | 9 G |
Enclosure Classification | IEC 60529 IP67 (NEMA6) | IEC 60529 IP67 (NEMA6) | IEC 60529 IP67 (NEMA6) |
Protection Circuit (NOTE 5) | 4 | 3, 4 | 3, 4 |
NOTE:
- WARNING: Never exceed rating (Watt=Voltage x Amperage). Permanent demage to sensor will occur.
- It bases on conditions of voltage 24 V DC, ambient temp. 25 °C and 2 meters cable of sensor. Voltage drop increases in pace with cable length.
- Measuring standard target: ø15.5Xø8X5t (Anisotropy rubber magnet)
- Sin wave / X , Y , Z 3 directions / 3 times each direction / 11 ms each time.
- Double amplitude 1.5 mm / 10Hz~55Hz~10Hz (Sweep 1 min) / X , Y , Z 3 directions / 1 hour each time.
- 1=None / 2=Short-circuit / 3=Power Source Reverse polarity / 4=Surge Suppression