Magnetic Sensors

CS-1000D - Weld-field immune sensor (Clamp mount)

SPECIFICATIONS

Type CS-1000D
Wiring Method 2-Wire Type
Switching Logic Solid State Output, Normally Open
Sensor type --
Operating Voltage 10~28V DC
Switching Current 5-50mA max.
Contact Rating (NOTE 1) 1.5W max.
Current Consumption --
Voltage Drop 5V max.
Leakage current Less Then 1 mA
Indicator Red LED:unstable sensing range  Green LED: stable sensing range
Cable Ø5.4, 2C, PVC
Operating Time 50 ms max.
Magnetic Field Resistance (NOTE 5) 16000A
Magnet Requirement (NOTE 2) 85 Gauss Parallel
Temperature Range -10~60℃(+14~140℉)
Shock (NOTE 3) 30 G
Vibration (NOTE 4) 9 G
Enclosure Classification IEC 60529 IP67 (NEMA 6)
Protection Circuit Surge Suppression, Reverse Polarity

NOTE:

  1. WARNING: Never exceed rating (Watt=Voltage x Amperage). Permanent demage to sensor will occur.
  2. Measuring standard target: ø15.5Xø8X5t (Anisotropy rubber magnet)
  3. Sin wave / X , Y , Z 3 directions / 3 times each direction / 11 ms each time.
  4. Double amplitude 1.5 mm / 10Hz~55Hz~10Hz (Sweep 1 min) / X , Y , Z 3 directions / 1 hour each time.
  5. 1=None / 2=Short-circuit / 3=Power Source Reverse polarity / 4=Surge Suppression